The module TANKER is intended for POL, oil products, alcohol, kerosene, solvent and other fluid (depending on the version) pumping and metering. The module can solve various problems tank parks can have under different operation conditions.

Equipment for the module is used both in the general industrial and explosion-proof version. The module is made in various design options — stationary or a mobile one on the automatic chassis.

The module frame is manufactured from a light-weight non-circular pipe. Painted in various colours with a high quality paint. The frame is equipped with supports or wheels or transporting lugs. The modules is custom-made in compliance with the customer’s requirements. The module key characteristics depend on the equipment used in it.

Technical characteristics

Precision of meter measurement

From 0.2 up to 1%

NB

From 15 up to 150 mm

Ambient temperature

from -40 to +50

Self-suction

Depends on the pump — up to 5 — 7 meters

Performance

From 40 to 500 lpm

Filtration

From 5 to 150 micron

Supply voltage

12V, 24V, 220V, 380V, motor pump