A non-clogging self-priming motor pump is used in urban waste water and industrial waste cleaning systems. Motor pumps Tanker-CT are characterized by optimal hydraulic parameters and a long service life.

Application area

  • incombustible and non-explosive liquids
  • rain water and normal waste
  • urban sewage, construction sites, drainage pump stations
  • industrial waste of consumer, paper, textile, food and chemical industrial companies, power stations, mines etc.
  • sewage waste in residential
  • sewage and ground water cleaning system water
  • tanning industry, waste of slaughter houses, river and pond fish farms
  • wine and sugar industry
  • transmission of mildly corrosive but heavily polluted waste

Technical characteristics

Model

Rotations per minute

Performance

Head

Capacity

NB input (output)

Diameter of particles

Self-priming lift

m3/h

1/s

m

kW

horse powers

mm

mm

m

TANKER-ST.665.50

1450

20

5.6

6.5

1.5

2

50 (2')

38

6.5

TANKER-ST.1415.80

1450

55

15.3

11.5

5.5

7.5

80 (3')

63

6.4

TANKER-ST.2250.100

1450

100

27.8

13.5

11

15

100 (4')

76

7.6

TANKER-ST.4665.150

1450

250

69.4

17

30

40

150 (6')

76

7.0

TANKER-ST.8330.200

1450

500

138.9

26

75

102

200 (8')

76

7

TANKER-ST.10000.250

1450

600

167

31

90

122

250 (10')

76

6.7

Посмотреть весь каталог и цены на товары в формате PDF   Задайте свой вопрос в Viber