A self-priming vane electrical pump is intended for diesel fuel and petrol pumping. The pump can be used both for independent pumping and as a part of stationary and mobile fuel dispenser, modular and stationary pump stations, liquid-fuel boiler plants. Hoisting height up to 5 meters. The product is pumped without filling the pump body with fluid. The pump TANKER is supplied with a single-phase or three-phase explosion-proof drive.
Technical characteristics of pump tanker
A filtering mesh is installed at the pump input. The pump is equipped with a bypass. Pressure at the bypass: up to 4 atm. The pump can be connected to a hydraulic circuit with the help of flanges. Sealings: Viton and bituminous-rubber cement.
Technical characteristics
Name |
Engine |
Rotation/ min. |
NB |
Weight, kg |
|||
Performance m3/h |
Single-phase |
Three-phase |
Capacity, W |
||||
V |
V |
||||||
TANKER 100 (l/m) |
6 |
220 |
380 |
750 |
1500 |
40 mm |
32.0 |
TANKER 150 (l/m) |
9 |
no |
380 |
1500 |
3000 |
40 mm |
35.0 |
- Pressure at the bypass: up to 4atm.
- Self-priming lift — up to 5 meters.
- Operation temperature: -40 + 60
- Protection class: IP54, Ex